Sign In | Join Free | My burrillandco.com
Home > Inverter Brake Unit >

50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical

Shenzhen K-Easy Electrical Automation Company Limited
Contact Now
    Buy cheap 50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical from wholesalers
     
    Buy cheap 50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical from wholesalers
    • Buy cheap 50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical from wholesalers
    • Buy cheap 50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical from wholesalers
    • Buy cheap 50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical from wholesalers
    • Buy cheap 50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical from wholesalers
    • Buy cheap 50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical from wholesalers
    • Buy cheap 50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical from wholesalers

    50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical

    Ask Lasest Price
    Brand Name : K-EASY
    Model Number : Inverter brake unit
    Certification : CE And ISO Certificated
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 30000 Sets Per Month
    Delivery Time : 1~7days
    • Product Details
    • Company Profile

    50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical

    K-DRIVE Original New Brake Unit for 220V 380V 400V Class Inverter


    Brand: K-Drive
    Certificate: CE, RoHS

     
    Product TypeRated Current(A)Crest CurrentMinimum ResistanceSize(mm)TerminalsDrawing Number
    LL1WW1H
    CDBR-201515A50A10Ω2402288555153M4Figure 1
    CDBR-202225A75A6.8Ω2402288555153M4
    CDBR-203030A85A2402288555153M4
    CDBR-403015A50A20Ω2402288555153M4
    CDBR-404525A75A13.6Ω2402288555153M4
    CDBR-405530A85A12Ω2402288555153M4
    CDBR-4075M35A100A10Ω2402288555153M4
    CDBR-407535A100A320304187120163M6Figure 2
    CDBR-411050A150A6.8Ω320304187120163M6
    CDBR-416070A200A320304187120163M6
    CDBR-422085A300A3.3Ω320304187120163M6
    CDBR-4300120A400A2.5Ω320223193304160M6


    50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical50Hz 60Hz Resistor Inverter Brake Unit 220V 380V 400V Practical


    Production

    In production, rigorous quality control is implemented on components, circuit boards, and the finished goods, assuring products without defects.


    How install the quality of inverter braker unit?

    The installation process for an inverter breaker unit can vary depending on the specific unit and the application. However, here are some general steps that can guide you through the process:


    Note: This is a general guide, and the specific installation process may vary depending on the unit and application. It is important to follow the manufacturer's instructions and local electrical codes. If you are not familiar with electrical work, it is recommended to seek the assistance of a licensed electrician.

    1. Read the manufacturer's instructions carefully: Before starting the installation, read the manufacturer's instructions and safety precautions carefully. Make sure that you understand the installation process, the wiring requirements, and any other important details.

    2. Choose a suitable location: Choose a location that is suitable for the inverter breaker unit. It should be in a cool, dry, and well-ventilated area, away from direct sunlight, dust, and other contaminants.

    3. Mount the unit: Mount the inverter breaker unit on a suitable surface using appropriate mounting hardware. Make sure that the unit is secure and that there is enough clearance around it for proper ventilation.

    4. Connect the power supply: Connect the power supply wires to the appropriate terminals on the unit. The power supply wires should be sized according to the manufacturer's recommendations and local electrical codes.

    5. Connect the load: Connect the load wires to the appropriate terminals on the unit. Again, the load wires should be sized according to the manufacturer's recommendations and local electrical codes.

    6. Connect the control wires: Connect the control wires to the appropriate terminals on the unit. These wires will be used to control the operation of the inverter breaker unit, such as turning it on and off or adjusting the speed.

    7. Test the unit: Once the installation is complete, test the inverter breaker unit to make sure that it is working properly. Follow the manufacturer's instructions for testing and commissioning the unit.

    8. Maintenance: Regular maintenance of the inverter breaker unit is essential to ensure its continued safe and reliable operation. Follow the manufacturer's instructions for maintenance and inspection of the unit.